The surface layer consists of UV‑stabilized polypropylene copolymer blended with impact‑modifying additives, providing a flexural modulus of approximately 1.8 GPa and a Shore A hardness of 85±3. This combination resists cracking under repeated ball impact while maintaining dimensional stability across temperature ranges from –20 °C to +50 °C.
A recycled rubber granule underlay, typically 5 mm thick, contributes a dynamic stiffness of 120 kN/m, enhancing shock absorption and reducing transmitted forces to the sub‑base. The underlay is bonded to the surface layer using a hot‑melt polyurethane adhesive with a shear strength exceeding 0.4 MPa.
Both layers are co‑extruded to ensure a seamless interface, eliminating delamination points that commonly arise in laminated systems.
| Property | Typical Value | Test Method |
|---|---|---|
| Thickness (total) | 13 mm ± 0.5 mm | ISO 24346 |
| Vertical deformation | 2.3 mm ± 0.3 mm | EN 14808 |
| Shock absorption | 48 % ± 4 % | ASTM F2772 |
| Slip resistance (wet) | SRV ≥ 55 | EN 13036‑4 |
| UV stability (color change ΔE) | < 4 after 1500 h QUV | ISO 4892‑3 |
Under repeated basketball impact (standard 60 J drop test), the flooring exhibits less than 0.2 mm permanent set after 10 000 cycles, indicating low permanent deformation.
Thermal expansion coefficient of the polypropylene layer is approximately 1.2 × 10⁻⁴ /°C, requiring expansion gaps of 6 mm per 10 m of installed length to accommodate seasonal temperature swings.
Acoustic testing shows a reduction of impact noise by 12 dB compared to bare concrete, improving player comfort in indoor‑adjacent outdoor settings.

Prepare a compacted gravel base with a minimum bearing capacity of 150 kPa, followed by a 50 mm layer of crushed stone graded to 0‑20 mm for drainage.
Lay a geotextile separator to prevent fine migration, then place the flooring panels interlocking via a tongue‑and‑groove system designed for lateral shear transfer of up to 0.6 kN per joint.
Secure perimeter edges with stainless steel anchors spaced at 600 mm intervals; allow 24 h curing of adhesive before subjecting the surface to load.
The product is suited for community recreation facilities where a durable, low‑maintenance surface must withstand both athletic use and environmental exposure.
Because the surface provides consistent ball rebound (coefficient of restitution 0.82 ± 0.03) and adequate slip resistance, it meets the performance criteria outlined in FIBA Outdoor Court Guidelines.
Installations over existing asphalt or concrete substrates are common, as the modular system accommodates minor substrate irregularities without extensive leveling work.
Each batch undergoes melt flow index testing (target 7–9 g/10 min) to confirm polymer consistency before extrusion.
Finished panels are inspected for thickness variation using laser profilometry, with acceptance criteria of ±0.4 mm across a 1 m² area.
UV stability is verified by accelerated weathering; panels exceeding ΔE = 4 are rejected.
Yes, the interlocking panel system allows for any rectangular layout; panels can be cut on site to accommodate irregular boundaries.
Project area, desired thickness, color preference, sub‑base condition, and any specific performance targets (e.g., shock absorption level).
Dimensional checks, UV stability testing, and mechanical property verification are performed per ISO standards before shipment.
Panels are stacked on pallets with corner protectors and stretch‑film wrapped; optional wooden crates for overseas transport.
Pallets are secured with steel straps and placed inside sealed containers; moisture‑absorbing desiccants are included to prevent condensation.
For project‑specific pricing, lead times, or sample requests, please reach out via the contact form.
Request Quotation